Test-Retest Reliability of 3D Ultrasound Measurements of the Thoracic Spine

Loading...
Thumbnail Image

Date

2012

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier Science Inc

Research Projects

Organizational Units

Journal Issue

Abstract

Objective: To explore the reliability of the Zebris CMS 20 ultrasound analysis system with pointer application for measuring end-range flexion, end-range extension, and neutral kyphosis angle of the thoracic spine. Setting: The study was performed within the School of Physiotherapy in cooperation with the Orthopedic Department at a University Hospital. Participants: The thoracic spines of 28 healthy subjects were measured. Methods: Measurements for neutral kyphosis angle, end-range flexion, and end-range extension were taken once at each time point. The bone landmarks were palpated by one examiner and marked with a pointer containing 2 transmitters using a frequency of 40 kHz. A third transmitter was fixed to the pelvis, and 3 microphones were used as receiver. The real angle was calculated by the software. Bland-Altman plots with 95% limits of agreement, intraclass correlations (ICC), standard deviations of mean measurements, and standard error of measurements were used for statistical analyses. The test-retest reliability in this study was measured within a 24-hour interval. Main Outcome Measurements: Statistical parameters were used to judge reliability. Results: The mean kyphosis angle was 44.8 degrees with a standard deviation of 17.3 degrees at the first measurement and a mean of 45.8 degrees with a standard deviation of 16.2 degrees the following day. The ICC was high at 0.95 for the neutral kyphosis angle, and the Bland-Altman 95% limits of agreement were within clinical acceptable margins. The ICC was 0.71 for end-range flexion and 0.34 for end-range extension, whereas the Bland-Altman 95% limits of agreement were wider than with the static measurement of kyphosis. Compared with static measurements, the analysis of motion with 3-dimensional ultrasound showed an increased standard deviation for test-retest measurements. Conclusions: The test-retest reliability of ultrasound measuring of the neutral kyphosis angle of the thoracic spine was demonstrated within 24 hours. Bland-Altman 95% limits of agreement and the standard deviation of differences did not appear to be clinically acceptable for measuring flexion and extension. PM R 2012;4:335-341

Description

Keywords

Citation

Collections

Endorsement

Review

Supplemented By

Referenced By