Publication:
On the accuracy of a moving average algorithm for target tracking during radiation therapy treatment delivery

dc.bibliographiccitation.firstpage2356
dc.bibliographiccitation.issue6
dc.bibliographiccitation.journalMedical Physics
dc.bibliographiccitation.lastpage2365
dc.bibliographiccitation.volume35
dc.contributor.authorGeorge, Rohini
dc.contributor.authorSuh, Yelin
dc.contributor.authorMurphy, Martin
dc.contributor.authorWilliamson, Jeffrey
dc.contributor.authorWeiss, Elizabeth
dc.contributor.authorKeall, Paul J.
dc.date.accessioned2018-11-07T11:14:48Z
dc.date.available2018-11-07T11:14:48Z
dc.date.issued2008
dc.description.abstractReal-time tumor targeting involves the continuous realignment of the radiation beam with the tumor. Real-time tumor targeting offers several advantages such as improved accuracy of tumor treatment and reduced dose to surrounding tissue. Current limitations to this technique include mechanical motion constraints. The purpose of this study was to investigate an alternative treatment scenario using a moving average algorithm. The algorithm, using a suitable averaging period, accounts for variations in the average tumor position, but respiratory induced target position variations about this average are ignored during delivery and can be treated as a random error during planning. In order to test the method a comparison between five different treatment techniques was performed: (1) moving average algorithm, (2) real-time motion tracking, (3) respiration motion gating (at both inhale and exhale), (4) moving average gating (at both inhale and exhale) and (5) static beam delivery. Two data sets were used for the purpose of this analysis: (a) external respiratory-motion traces using different coaching techniques included 331 respiration motion traces from 24 lung-cancer patients acquired using three different breathing types [free breathing (FB), audio coaching (A) and audio-visual biofeedback (AV)]; (b) 3D tumor motion included implanted fiducial motion data for over 160 treatment fractions for 46 thoracic and abdominal cancer patients obtained from the Cyberknife Synchrony. The metrics used for comparison were the group systematic error (M), the standard deviation (SD) of the systematic error (Sigma) and the root mean square of the random error (sigma). Margins were calculated using the formula by Stroom [Int. J. Radiat. Oncol., Biol., Phys. 43(4), 905-919 (1999)]: 2 Sigma+0.7 sigma. The resultant calculations for implanted fiducial motion traces (all values in cm) show that M and Sigma are negligible for moving average algorithm, moving average gating, and real-time tracking (i.e., M and Sigma=0 cm) compared to static beam (M=0.02 cm and Sigma=0.16 cm) or gated beam delivery (M=-0.05 and 0.16 cm at both exhale and inhale, respectively, and Sigma=0.17 and 0.26 cm at both exhale and inhale, respectively). Moving average algorithm sigma=0.22 cm has a slightly lower random error than static beam delivery sigma=0.24 cm, though gating, moving average gating, and real-time tracking have much lower random error values for implanted fiducial motion. Similar trends were also observed for the results using the external respiratory motion data. Moving average algorithm delivery significantly reduces M and Sigma compared with static beam delivery. The moving average algorithm removes the nonstationary part of the respiration motion which is also achieved by AV, and thus the addition of the moving average algorithm shows little improvement with AV. Overall, a moving average algorithm shows margin reduction compared with gating and static beam delivery, and may have some mechanical advantages over real-time tracking when the beam is aligned with the target and patient compliance advantages over real-time tracking when the target is aligned to the beam. (C) 2008 American Association of Physicists in Medicine.
dc.description.sponsorshipNCI NIH HHS [R01 CA093626, R01 CA 93626]
dc.identifier.doi10.1118/1.2921131
dc.identifier.isi000256305600025
dc.identifier.pmid18649469
dc.identifier.urihttps://resolver.sub.uni-goettingen.de/purl?gro-2/54222
dc.notes.statuszu prüfen
dc.notes.submitterNajko
dc.publisherAmer Assoc Physicists Medicine Amer Inst Physics
dc.relation.issn0094-2405
dc.titleOn the accuracy of a moving average algorithm for target tracking during radiation therapy treatment delivery
dc.typejournal_article
dc.type.internalPublicationyes
dc.type.peerReviewedyes
dc.type.statuspublished
dspace.entity.typePublication