Publication:
Non-destructive, preclinical evaluation of root canal anatomy of human teeth with flat-panel detector volume CT (FD-VCT)

dc.bibliographiccitation.firstpage1683
dc.bibliographiccitation.issue12
dc.bibliographiccitation.journalROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN
dc.bibliographiccitation.lastpage1690
dc.bibliographiccitation.volume177
dc.contributor.authorHeidrich, Gabert
dc.contributor.authorHassepass, F.
dc.contributor.authorDullin, Christian
dc.contributor.authorAttin, T.
dc.contributor.authorGrabbe, Eckhard
dc.contributor.authorHannig, C.
dc.date.accessioned2018-11-07T10:54:02Z
dc.date.available2018-11-07T10:54:02Z
dc.date.issued2005
dc.description.abstractPurpose: Successful endodontic diagnostics and therapy call for adequate depiction of the root canal anatomy with multimodal diagnostic imaging. The aim of the present study is to evaluate visualization of the endodont with flat-panel detector volume CT (FD-VCT). Materials and Methods: 13 human teeth were examined with the prototype of a FD-VCT. After data acquisition and generation of volume data sets in volume rendering technology (VRT), the findings obtained were compared to conventional X-rays and cross-section preparations of the teeth. Results: The anatomical structures of the endodont such as root canals, side canals and communications between different root canals as well as denticles could be detected precisely with FD-VCT. The length of curved root canals was also determined accurately. The spatial resolution of the system is around 140 pm. Only around 73% of the main root canals detected with FD-VCT and 87% of the roots could be visualized with conventional dental X-rays. None of the side canals, shown with FD-VCT, was detectable on conventional X-rays. In all cases the enamel and dentin of the teeth could be well delineated. No differences in image quality could be discerned between stored and freshly extracted teeth, or between primary and adult teeth. Conclusion: FD-VCT is an innovative diagnostic modality in preclinical and experimental use for non-destructive three-dimensional analysis of teeth. Thanks to the high isotropic spatial resolution compared with conventional X-rays, even the minutest structures, such as side canals, can be detected and evaluated. Potential applications in endodontics include diagnostics and evaluation of all steps of root canal treatment, ranging from trepanation through determination of the length of the root canal to obturation.
dc.identifier.doi10.1055/s-2005-858557
dc.identifier.isi000234084100012
dc.identifier.pmid16333792
dc.identifier.urihttps://resolver.sub.uni-goettingen.de/purl?gro-2/49477
dc.notes.statuszu prüfen
dc.notes.submitterNajko
dc.publisherGeorg Thieme Verlag Kg
dc.relation.issn1438-9029
dc.titleNon-destructive, preclinical evaluation of root canal anatomy of human teeth with flat-panel detector volume CT (FD-VCT)
dc.typejournal_article
dc.type.internalPublicationyes
dc.type.peerReviewedyes
dc.type.statuspublished
dspace.entity.typePublication

Files

Collections