Publication:
Aptamer Stainings for Super-resolution Microscopy

dc.bibliographiccitation.firstpage197
dc.bibliographiccitation.lastpage210
dc.contributor.authorGomes de Castro, Maria Angela
dc.contributor.authorRammner, Burkhard
dc.contributor.authorOpazo, Felipe
dc.contributor.editorMayer, Günter
dc.date.accessioned2023-06-26T12:46:18Z
dc.date.available2023-06-26T12:46:18Z
dc.date.issued2016
dc.description.abstractFluorescence microscopy is an invaluable tool to visualize molecules in their biological context with ease and flexibility. However, studies using conventional light microscopy have been limited to the resolution that light diffraction allows (i.e., ~200 nm). This limitation has been recently circumvented by several types of advanced fluorescence microscopy techniques, which have achieved resolutions of up to ~10 nm. The resulting enhanced imaging precision has helped to find important cellular details that were not visible using diffraction-limited instruments. However, it has also revealed that conventional stainings using large affinity tags, such as antibodies, are not accurate enough for these imaging techniques. Since aptamers are substantially smaller than antibodies, they could provide a real advantage in super-resolution imaging. Here we compare the live staining of transferrin receptors (TfnR) obtained with different fluorescently labeled affinity probes: aptamers, specific monoclonal antibodies, or the natural receptor ligand transferrin. We observed negligible differences between these staining strategies when imaging is performed with conventional light microscopy (i.e., laser scanning confocal microscopy). However, a clear superiority of the aptamer tag over antibodies became apparent in super-resolved images obtained with stimulated emission depletion (STED) microscopy.
dc.identifier.doi10.1007/978-1-4939-3197-2_17
dc.identifier.pmid26552828
dc.identifier.urihttps://resolver.sub.uni-goettingen.de/purl?gro-2/128771
dc.item.fulltextNo Fulltext
dc.language.isoen
dc.relation.ispartofNucleic Acid Aptamers: Selection, Characterization, and Application
dc.relation.orgunitInstitut für Neuro- und Sinnesphysiologie
dc.relation.orgunitDFG Forschungszentrum Molekularphysiologie des Gehirns und Exzellenzcluster Mikroskopie im Nanometerbereich
dc.relation.orgunitUniversitätsmedizin Göttingen
dc.titleAptamer Stainings for Super-resolution Microscopy
dc.typebook_chapter
dc.type.internalPublicationyes
dspace.entity.typePublication

Files

Collections