Publication:
Intra- and interobserver variability in the diagnosis of GERD by real-time MRI

dc.bibliographiccitation.firstpage14
dc.bibliographiccitation.journalEuropean Journal of Radiology
dc.bibliographiccitation.lastpage19
dc.bibliographiccitation.volume104
dc.contributor.authorHosseini, Ali Seif Amir
dc.contributor.authorBeham, Alexander Wilhelm
dc.contributor.authorUhlig, Johannes
dc.contributor.authorStreit, Ulrike
dc.contributor.authorUhlig, Annemarie
dc.contributor.authorEllenrieder, Volker
dc.contributor.authorJoseph, Arun A.
dc.contributor.authorVoit, Dirk
dc.contributor.authorFrahm, Jens
dc.contributor.authorUecker, Martin
dc.contributor.authorLotz, Joachim
dc.contributor.authorBiggemann, Lorenz
dc.date.accessioned2020-05-13T13:45:25Z
dc.date.available2020-05-13T13:45:25Z
dc.date.issued2018
dc.description.abstractThe purpose of this study was to assess the reproducibility of functional and anatomical parameters of swallowing events as determined by real-time MRI at 40 ms temporal resolution (25 frames per second). Twenty-three consecutive patients with gastroesophageal reflux disease (GERD) underwent real-time MRI of the gastroesophageal junction at 3.0 T. Real-time MRI was based on highly undersampled radial fast low angle shot (FLASH) acquisitions with iterative image reconstruction by regularized nonlinear inversion (NLINV). MRI movies visualized the esophageal transport of a pineapple juice bolus, its passage through the gastroesophageal junction and functional responses during a Valsalva maneuver. His-angle, sphincter position, sphincter length and sphincter transit time were assessed by two radiologists. Interobserver and intraobserver intraclass correlation coefficients (ICC) were evaluated and Bland-Altman plots were constructed to assess the observer agreement. Interobserver agreement was excellent for sphincter transit time (ICC = 0.92), His-angle (ICC = 0.93), His-angle during Valsalva maneuver (ICC = 0.91) and sphincter-to-diaphragm distance (ICC = 0.98). Sphincter length and oesophageal diameter showed good interobserver agreement (ICC = 0.62 and ICC = 0.70). Intraobserver agreement was good for sphincter length (ICC = 0.80) and excellent for sphincter transit time, His-angle and His-angle during Valsalva maneuver, sphincter-to-diaphragm distance, and esophageal diameter (ICC = 0.91; ICC = 0.97; ICC = 0.97; ICC = 0.998; ICC = 0.93). All functional parameters of the gastroesophageal junction had good to excellent reproducibility. Visual assessment of Bland Altman plots did not reveal any systematic interobserver bias. In conclusion, the visualization of swallowing events by real-time MRI has a high potential for clinical application in gastroesophageal reflux disease.
dc.identifier.doi10.1016/j.ejrad.2018.04.029
dc.identifier.pmid29857860
dc.identifier.urihttps://resolver.sub.uni-goettingen.de/purl?gro-2/65371
dc.language.isoen
dc.relation.eissn1872-7727
dc.relation.issn0720-048X
dc.titleIntra- and interobserver variability in the diagnosis of GERD by real-time MRI
dc.typejournal_article
dc.type.internalPublicationyes
dspace.entity.typePublication

Files

Collections